interface fluidics white logo
Fracture Fluid Performance (Flowback) Chip with 120 nm Matrix, and 4 Ports

Fracture Fluid Performance (Flowback) Chip with 120 nm Matrix, and 4 Ports

SKU: 300005
The patented Flowback S100 Chip powers our industry-leading Flowback test and is designed to represent the pore geometries of shale formations during hydraulic fracturing, and includes four inlets/outlets, a high permeability frac zone, a surrounding nano matrix (with oil pockets) and oil accumulation channels. The Flowback test enables visualization and measurement of how surfactants, friction reducers, and fluid packages interact within representative porous media during hydraulic fracturing. The test helps to identify top-performing fluid packages and visually reveal formation damage mechanisms.

Use Cases

Fracture Fluid Performance (Screening)

Specifications

Porous Media Specifications

Frac Zone: - Pore Throats: 5-25 μm wide, 25 μm deep - Porosity: 34.5% - Permeability: 40 D (calculated) - Volume: 12 nL Matrix Oil Pockets: - Size: 50-100 μm wide, 25 μm deep - Porosity: 5.4% - Permeability: 2.5 μD (calculated) - Volume: 5.3 nL Matrix Nanonetwork: - Size: 10 μm wide, 120 nm deep - Porosity: 5.4% - Permeability: 2.5 μD (calculated) - Volume: 0.09 nL

Channel Specifications

Inlets, Outlets and Accumulation Channels: 50 μm wide, 25 μm deep

Number of Ports

4

Holder Compatibility

Screw Top Liquid Confined

Interface Fluidics

SapphireLab® Pro+

A compact system designed to be a modern replacement for the PVT cell, slim tube and rising bubble apparatus. Provides ultimate flexibility, full heat tracing of the fluid path, live sample handling, and optional sour service.

Learn More